54
Installation requirements vary in different districts, and the local building officials have the final
authorization to approve your installation. You should discuss the installation with them before
beginning. Please ask your dealer for further information.
Do not connect to any air distribution duct or system.
Important: If the installation instructions are not followed carefully, it may cause
dangerous situations like chimney - and house fires. Follow the instructions
carefully and do not deviate from them as it may cause injuries to people or
property.
1.1 Unpacking the stove
After removing the outer packaging place it gently on its back. The cardboard packaging can be
placed underneath to prevent marring. Remove the leg pack from the stove and bolt each leg/
panel securely to the underside of the base on the combustion chamber, using the bolts provided
(found inside the stove).
We recommend that two people perform the assembly and installation procedure.
The Morsø 2110 weighs 125 kg.).
1.2 Checking loose parts in the stove
After unpacking, check that the fire bricks are firmly in position and have not shifted in transit.
Check also that the air control works freely.
Standard Accessories
Poker, ceramic flue connection gasket and ash can tools are standard accessories, and can
usually be found in the ashpan or firebox area.
1.3 The chimney / flue system
Note that the flue system must be independently secured and must not rely on the stove for
support.
The stove must not be connected to a chimney flue serving any other appliance.
(Several flues may run up a single chimney stack; use one flueway per appliance).
Use a residential type masonry or listed type HT factory-built chimney.
High Temperature (H.T.) Chimney Standard UL-103-1985 (2100º F.) for the USA, and High
Temperature (650ºC) Standard ULC S-629 for Canada.
The internal dimensions of the chimney connector and chimney must not be less than 6 inches
diameter (or equivalent cross section), and should not be significantly larger than this. Too
large a section will tend to allow the flue gases to cool excessively, causing sluggishness or
unpredictability in the stove’s performance.
We recommend the length of the chimney system should be at least 16 feet (not required) above
the stove in normal domestic situations, measured from the flue collar to the top of the chimney.
Local conditions like for example - roof constructions, large trees nearby and high altitude, may
influence the chimney draft and height. Therefore, contact the local professional chimney sweep
or your Morsø dealer.
1.0 Installation of your Morsø stove
Installation of woodburning stoves must be safe and legal.
If your Morsø stove is not installed correctly, it may cause a house fire. To reduce
the risk of fire, the installation instructions must be followed carefully. Contact the
local building officials about restrictions and installation inspection in your area.
Before you start installing your stove, make sure that:
- The stove and chimney connection are placed far enough from combustible materials to meet
all clearance requirements.
- The floor protection must be adequate and must be made correctly according to ´the
requirements.
All neccessary approvals are needed from the local building officials.
The data plate, which is located on the back of the stove, provides information regarding safety
testing information, name of certified testing laboratory, and installation requirements.
Typical Factory-Built or Masonry Chimney Installations